+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Cypress S25FL512SAGMHAG10 SOIC(16) Device

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT: Algorithm support for this device selection is developed. Device samples are needed for QA testing and full release in BPWin.For information on how to obtain an expedited release of this device support please contact BPM Microsystems at:Inside Sales713–688-4600inside_sales@bpmmicro.comInformation on expected socket module support can be found our web page at: http://www.www.bpmmicro.com/find-your-device/**Please note that receipt of device samples and QA testing must be completed before socket module support can be validated.

Device Type: SPI Flash Memory
Device Size: 512M-bit
Algorithm Programming Method: SPI


Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address(hex)(if this area is selected/Activated) BPWin Buffer Byte Address(hex)
Main Flash Area R/W/E Yes 0000_0000 – 03FF_FFFF 0000_0000 – 03FF_FFFF
OTP R/W No 0400_0010 – 0400_03FF 0400_0010 – 0400_03FF
Password R/W No 0400_0400 – 0400_0407 0400_0400 – 0400_0407
Default Algorithm Range 0000_0000 – 03FF_FFFF 0000_0000 – 03FF_FFFF

* R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device->Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:

1. Serialization Supported: Yes
2. The Factory Programmed 128-bit random number located at the beginning of the OTP regioncannot be programmed. The data in this number will not be shown in the Buffer Editor.
3. OTP Lock bits are located in Buffer Addresses [0400_0010h – 0400_0013h]. If any of these bitsare programmed this algorithm will not be able to program additional bits in the OTP region.
4. OTP Reserved bits are located in Buffer Addresses [0400_0014h – 0400_001Fh].
5. The correct password value located in Buffer Addresses [0400_0400h – 0400_0407h] may only be readbefore the Password Protection Mode in the ASP Register (ASP[2]) bit has been programmed to ‘0’.
5. The Persistent Protection Bits (PPB) may be programmed under Device->Settings.Each Group is divided into 256K-Byte blocks of data. This is condensed version of PPBAR for each sector.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

8-bit Bytes

67109896

Manufacturer

Cypress

Packages

SOIC(16)

Part Number

S25FL512SAGMHAG10

Set programming

Yes

Vcc(program)

3.6