Cypress CYPD3125-40LQXIT LAP(40) Device

Adapters for Automated Programmers

8th Gen 9th Gen
FVE4ASMR40QFNWA, FVE4ASMR40QFNWA FVE4ASMR40QFNWA

Adapters for Manual Programmers

8th Gen 9th Gen
FVE4ASMR40QFNWA, FVE4ASMR40QFNWA FVE4ASMR40QFNWA

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT:

Device Type: 32-bit MCU Flash Microcontroller.


Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address(hex)(if this area is selected/Activated) BPWin Buffer Byte Address(hex)
User Flash R/W/E Yes 0000_0000 – 0001_FFFF 0000_0000 – 0001_FFFF
User Check sum R Yes 9030_0000 – 9030_0001 9030_0000 – 9030_0001
Flash Protectition R/W/E Yes 9040_0000 – 9040_007F 9040_0000 – 9040_007F
Chip Level Protection R Yes 9060_0000 – 9060_0000 9060_0000 – 9060_0000

* R:Read only W:One time programmable (OTP) R/W:readable and one time programmable (OTP) R/W/E:readable and rewritable if not locked. Special Device Considerations:

1) User Flash 128KB: [0x0000-0x1FFFF]. 2)User Check sum 2bytes: [0x90300000-0x90300001]. This feature is for read only. 3) Flash protection 128 Bytes: [0x90400000-0x9040007F]. 4) Device Silicon ID: [0x90500000-0x9050000B]. This feature is for read only for the addresses [0x905000020x90500003 and 0x90500005]. 5) Chip Level Protection 1 byte: [0x90600000]: This feature is for read and verify only for the addresses [0x90600000]. * There are four states of Chip Level Protection into which the silicon can be moved:[ VIRGIN(0x00) OPEN(0x01) PROTECTED(0x02) KILL(0x04)]. – VIRGIN(0x00) – This mode is not for custom use. Can not program this value to device. – OPEN(0x01) – In this mode can access all the needed resources including Erase program and verify flash. – PROTECTED(0x02) – In this mode access to Flash is disabled. Still allow to Erase and reprogram flash. – KILL(0x04) – The device can no longer be updated. 6) The address [0x90600001] is ignored. Serialization is not supported.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

8-bit Bytes

2422210562

Manufacturer

Cypress

Packages

LAP(40)

Part Number

CYPD3125-40LQXIT

Set programming

Yes

Vcc(program)

3