+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Texas Instruments MSP430F2272IYFFR (FVE4ASML49BGT) BGA(49) Device

Adapters for Automated Programmers

8th Gen 9th Gen
FVE4ASML49BGT, FVE4ASML49BGT FVE4ASML49BGT

Adapters for Manual Programmers

8th Gen 9th Gen
FVE4ASML49BGT, FVE4ASML49BGT FVE4ASML49BGT

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT:

Device Type: Microcontroller with Flash EEPROM
Device Size: 32KB + 256B Flash Memory


Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address(hex)(if this area is selected/Activated) BPWin Buffer Byte Address(hex)
Main Flash Area R/W/E Yes 0000_4000-0000_7FFF 0000_8000-0000_FFFF
Information Memory R/W/E No 0000_0800-0000_087F 0000_1000-0000_10FF
Default Algorithm Range 0000_0000 – 0000_7FFF 0000_0000 – 0000_7FFF

* R:Read only W:One time programmable (OTP) R/W:readable and one time programmable (OTP) R/W/E:readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:

Buffer locations 0000h-0FFFh(device location 0000h-07FFh) and 1100h-7FFFh(device location 0880h-3FFF) are reserved and must contain data FFh. Each segment of the Information Memory and Main Memory may be Erased and Programmed separately. To access the Information Memory only set the Device Configure->Range between 0800h-087Fh (device address). Information Memory data will be displayed in buffer locations 1000h-10FFh.To access the Main Memory only set the Device Configure->Range between 4000h-7FFFh (device address).Main Memory data will be displayed in buffer locations 8000h-FFFFh.To access both Information and Main Memory set the range as 0000h-7FFFh (device address).To overwrite Calibration values at buffer location 10F8h-10FFh select in Device Configure.Otherwise by default factory calibration values are preserved.For Compare buffer location 10F8h-10FFh are ignored. Use Read to read those locations.Please note that SECURE is not erasable.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

Manufacturer

Texas Instruments

Packages

BGA(49)

Part Number

MSP430F2272IYFFR

Vcc(program)

3

Package