Adapters for Automated Programmers
8th Gen | 9th Gen |
FVE4ASMR20QFNV, FVE4ASMR20QFNV | FVE4ASMR20QFNV |
Adapters for Manual Programmers
8th Gen | 9th Gen |
FVE4ASMR20QFNV, FVE4ASMR20QFNV | FVE4ASMR20QFNV |
Adapters for Engineering Programmers
Last Updated: 05/18/2023
If the device is not yet supported by your BPM programmer (Generation), request Device Support
Note
IMPORTANT: [This is a custom algorithm]
Device Type: | Microcontroller |
Device Size: | 2 Kbyte |
Algorithm Programming Method: | Serial Programming |
Memory Organization:
Memory Type |
Attributes(*)
|
Included in default Range (Y/N) | DUT Physical Byte Address(hex)(if this area is selected/Activated) | BPWin Buffer Byte Address(hex) |
Program Memory | [R/W/E] | [Yes] | [000-7FF] | [000-7FF] |
[EEPROM Data Memory] | [R/W/E] | [Yes] | [ 800-87F] | [ 800-87F] |
Default Algorithm Range | — | — | [000-87F] | [000-87F] |
* R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:
Option | Description | Default | Supported (Y/N)? |
[Fuse Low Byte] | [Please see device specification for the setting][Warning: setting this option to [44] in hex will make the device unresponsive.] | [64] | [Yes] |
[Fuse High Byte ] | [Please see device specification for the setting] | [DF] | [Yes] |
[Fuse Extended Byte] | [Reserved bits should be set to 1] | [FF] | [Yes] |
[Calibration ] | [program the Calibration byte to the address specified by the next option] | [DISABLE] | [Yes] |
[CAL BYTE ADDRESS ] | [this option is to set one of the addresses (0h-01h) in the signature row high byte] | [0] | [Yes] |
[CALIBRATION ADDRESS] | [this option is set to one of the address (000h-87Fh) in the flash or EEPROM memory that Calibration] | [0] | [Yes] |
1. | Serialization Supported: | Yes |
2. | [Secure/Lock Erasable]: | Yes |
3. | [Special file format required]: | No |
4. | To program these calibration bytes under Device Configure1)Set CALIBRATION to ENABLE 2)Set CAL BYTE ADDRESS to one of the 2 Calibration Byte addresses [00h-01h]. 3)Set CALIBRATION ADDRESS to the memory address within [000h-87Fh] you want to program the Calibration Byte. | |
5. | Erasing the device clears all lockbits. In this algorithm Chip Erase is forced before any operation for a device with any lockbits programmed |
‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
Manufacturer | Atmel |
---|---|
Packages | LAP(20) |
Part Number | ATTINY2313A-MU |
Set programming | Yes |
Vcc(program) | 5 |
8-bit Bytes | |
Package |