+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Cypress CY8C3666AXI-052T TQFP(100) Device

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT: Algorithm support for this device selection is developed. Device samples are needed for QA testing and full release in BPWin.For information on how to obtain an expedited release of this device support please contact BPM Microsystems at:Inside Sales713–688-4600inside_sales@bpmmicro.comInformation on expected socket module support can be found our web page at: http://www.www.bpmmicro.com/find-your-device/**Please note that receipt of device samples and QA testing must be completed before socket module support can be validated.

Device Type: Programmable System-on-Chip
Device Size: 64K-Byte Code Flash + 8K-Byte Configuration Flash + 2K-Byte EEPROM
Algorithm Programming Method: SWD

Memory Organization:

Memory Type Attributes* Included in Default Range (Y/N) BPWin Buffer Byte Address(hex)
Code Flash R/W/E Yes 0000_0000 – 0000_FFFF
Configuration Flash R/W/E Yes 8000_0000 – 8000_1FFF
Device Configuration NVL R/W/E Yes 9000_0000 – 9000_0003
Write Once NVL R/W/E Yes 9010_0000 – 9010_0003
EEPROM R/W/E Yes 9020_0000 – 9020_07FF
Default Algorithm Range 0000_0000 – 9020_07FF

* R/W/E: readable and rewritable if not locked. Special Device Considerations:

1. Serialization is not supported.
2. The Configuration Flash is programmed read and erased when the Code Flash range is selected.
3. The Device Configuration NVL is programmed prior to programming the Code Flash.
4. If bit [3] of Data Buffer address 9000_0003h in the Device Configuration NVL is set to 1bthen ECC will be enabled and the data from Configuration Flash in the Data Buffer will not be used.If ECC is not enabled data will be read from the Data Buffer from address range 8000_0000h – 8000_1FFFh.
5. The Device Configuration NVL and Write Once NVL will only be programmedif the data in the Data Buffer mismatches what is read from the device.
6. Programming the Write Once NVL to 5053_6F43h will make the device One Time Programmable.
7. Checksum and Flash Protection are currently not supported.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

Manufacturer

Cypress

Packages

TQFP(100)

Part Number

CY8C3666AXI-052T

Vcc(program)

1.9

Package