+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Infineon(Siemens) IRPS5401MTRPBF QFN(56) Device

Adapters for Automated Programmers

7th Gen 9th Gen
FX4ASMR56QFNK, FASMR56QFNK, LX4ASMR56QFNK (repl.) LX4ASMR56QFNK

Adapters for Manual Programmers

7th Gen 9th Gen
FX4ASMR56QFNK, FASMR56QFNK, LX4ASMR56QFNK (repl.) LX4ASMR56QFNK

Adapters for Engineering Programmers

7th Gen
FX4ASMR56QFNK, FASMR56QFNK, LX4ASMR56QFNK (repl.)

Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT:

Device Type: Infineon Flexible Power Management Unit
Device Memory Type: Configuration Registers
Algorithm Programming Method: PMBus
Supported Data File Format: Single image three column configuration file
Serialization Supported: No

Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address(hex)(if this area is selected/Activated) BPWin Buffer Byte Address(hex)
Configuration Registers R/W/E Yes 0000 – 17FF Determined by data file
Default Algorithm Range 0000 – 17FF Determined by data file

* R/W/E: readable and rewritable if not locked. Configuration Register Mapping:

Section Switcher Register Range(hex) Enable Register(hex) and Bit
CNFG 0000 – 0001
User Common 0020 – 003A
User A 0420 – 043F0600 – 06FF0700 – 07FF 0038[0]
User B 0820 – 083F0A00 – 0AFF0B00 – 0BFF 0038[1]
User C 0C20 – 0C3F0E00 – 0EFF0F00 – 0FFF 0038[2]
User D 1020 – 103F1200 – 12FF1300 – 13FF 0038[3]
User LDO 1420 – 143F1600 – 16FF1700 – 17FF 0038[4]

Special Device Considerations:

1. Programming each section (CNFG User) can be enabled or disabledfor Program and Verify operations under Device->Settings.
2. The CNFG section is limited to five image writes.If the CNFG section is enabled and there are no more write attempts the Program operation will fail.
3. The User section is limited to 26 image writes.If the User section is enabled and there are no more write attempts the Program operation will fail.
4. The CNFG section should be programmed at least once.Otherwise the User section may not verify correctly.
5. This algorithm will only program and verify the register rangeslisted in the Configuration Register Mapping table above.The masks in the data file will determine which bits to verify.
6. By default all switcher registers will be verified. If register 0038h is specified in the data filethe data there will be used to determine which switcher registers to verify.See the Configuration Register Mapping table above for which bit corresponds to which switcher.A bit value of 0b will enable that switcher and 1b will disable it.
7. Operations on the TRIM section are not supported.
8. Check MTP operation checks how many writes are left in the USER/CNFG sections.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

8-bit Bytes

131072

Manufacturer

Infineon(Siemens)

Packages

QFN(56)

Part Number

IRPS5401MTRPBF

Vcc(program)

5

Package