Adapters for Automated Programmers
8th Gen | 9th Gen |
FVE2ASMR484BGTA, FVE2ASM484BGTB, FVE2ASMR484BGTA, FVE2ASM484BGTB | FVE2ASMR484BGT |
Adapters for Manual Programmers
8th Gen | 9th Gen |
FVE2ASMR484BGTA, FVE2ASM484BGTB, FVE2ASMR484BGTA, FVE2ASM484BGTB | FVE2ASMR484BGT |
Adapters for Engineering Programmers
Last Updated: 05/18/2023
If the device is not yet supported by your BPM programmer (Generation), request Device Support
Note
IMPORTANT:
Device Type: | 32-bit G3M CPU core |
Device Size: | 5MBytes Code Flash + 32KBytes User Area + 64KBytes Data Flash |
Algorithm Programming Method: | 3-Wire Serial I/O Mode |
Memory Organization:
Memory Type |
Attributes(*)
|
Included in default Range (Y/N) | DUT Physical Byte Address(hex)(if this area is selected/Activated) | BPWin Buffer Byte Address(hex) | Code Flash Memory | R/W/E | Yes | 0000 0000 – 004F FFFF | 0000 0000 – 004F FFFF | User Area Memory | R/W/E | Yes | 0100 0000 – 0100 7FFF | 0100 0000 – 0100 7FFF |
Data Flash Memory | R/W/E | Yes | FF20 0000 – FF20 FFFF | FF20 0000 – FF20 FFFF |
Default Algorithm Range | — | — | 0000 0000 – FF20 FFFF | 0000 0000 – FF20 FFFF |
* R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation. Special Device Considerations: Erase function for a Blank secured device is not supported. Security for this device is verified after performing Secure operation. The Security Byte can be set under Device > Configure and programmed with Secure command. In order to program this Byte please enable Secure. Set bit 5 to 0 to disable Erase set bit 6 to 0 to disable Program set bit 7 to 0 to disable Read. Bits 4 to 0 are reserved and should be set to 1s. *Bits 5 6 and 7 cannot be erased and once bit 5 is programmed to 0 the whole chip is secured. Once Validate ICU-S is set to True stand alone verify and compare will not be supported in the Data Flash range. Serialization is not supported. Verification for this device is performed using the internal CRC feature of the device. The Data Pattern CRC is compared and validated against the CRC value returned internally by the device. Device specifications provide details on how this CRC is calculated. ‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
8-bit Bytes | 4280352768 |
---|---|
Manufacturer | Renesas |
Packages | BGA(484) |
Part Number | R7F701412EABG |
Vcc(program) | 3.3 |
Package |