Adapters for Automated Programmers
9th Gen |
FVE2ASMR144QPW |
Adapters for Manual Programmers
9th Gen |
FVE2ASMR144QPW |
Adapters for Engineering Programmers
Last Updated: 05/18/2023
If the device is not yet supported by your BPM programmer (Generation), request Device Support
Note
IMPORTANT: [This is a custom algorithm. This algorithm has 32-bit precision in the DataFlash region.]
Device Type: | RH850G3M CPU core Microcontroller |
Device Size: | 2MB Code Flash + 32kB User Area + 64kB Data Flash |
Algorithm Programming Method: | 3-Wire Serial I/O Mode. |
Memory Organization:
Memory Type |
Attributes(*)
|
Included in default Range (Y/N) | DUT Physical Byte Address (hex)(if this area is selected/Activated) | BPWin Buffer Byte Address (hex) |
Code Flash | R/W/E | Yes | 0000_0000 – 001F_FFFF | 0000_0000 – 001F_FFFF |
User Area Flash | R/W/E | Yes | 0100_0000 – 0100_7FFF | 0100_0000 – 0100_7FFF |
Data Flash () | R/W/E | Yes | FF20_0000 – FF20_FFFF | FF20_0000 – FF20_FFFF |
Default Algorithm Range | — | — | 0000_0000 – FF20_FFFF | 0000_0000 – FF20_FFFF |
*R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Data Flash range is programmed & verified with 32-bit precision. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:
Option | Description |
Security Flag | Set Bit 5 to 0 will disable Erase. Set Bit 6 to 0 will disable Program. Set Bit 7 to 0 will disable Read.Bits 4 to 0 are reserved and should be set to 1s.The Security Byte cannot be erased and once bit 5 is programmed to 0the whole chip is secured and no further operations can be performed. |
1. | Verification for this device is performed using the internal CRC feature of the device. | |||||||||||||
The Data Pattern CRC is compared and validated against the CRC value returned internally by the device. | ||||||||||||||
Device specifications provide details on how this CRC is calculated. | ||||||||||||||
2. | Renesas Flash Programmer Image File (*.rpi) file format support added with features of ISEID code Option bytes. | |||||||||||||
3. | FlashOptions should be in correct-format in RPI file. | |||||||||||||
4. | The Security Flag and ID code can be set in the Secure command. | |||||||||||||
5. | Once ID code has been set under the Secure command. | |||||||||||||
the sample will check ID Authentication during all standard operations.it cannot be reset. | ||||||||||||||
6. | This algorithm supports Firmware version RH850 V3 or later. | |||||||||||||
7. | Once Validate ICU-S is set to True(i.e enabled ICU-S/ISE under FlashOptions).Stand-alone verify and compare will not be supported in the Data Flash range. | |||||||||||||
8. | Serialization is not supported. | |||||||||||||
9. | Loading an .rpi file automatically sets configurations and security. Configuration inputs are overwritten and cannot be changed.
|
ID Code bytes can only be programmed by loading an .rpi file with ID protection set(check RPI file thoroughly).
| 10. |
Unprogrammed parts of the Data Flash will be in the erased state and readback data is in an unkown state. |
11. |
Connect processing routines will attempt to unlock during every operation if the ID the is programmed once. |
|
And the Algo will read the deviceID/Electronic DevID as 00000000 if the ID Code Authentication Mode Get fails (i.e wrong ID Code password in RPI fileso don’t ignore the ID check). |
|
‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
8-bit Bytes | 4280352768 |
---|---|
Manufacturer | Renesas |
Packages | QFP(144) |
Part Number | R7F701421EAFB |
Set programming | Yes |
Vcc(program) | 3.3 |
Package |