+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Macronix MX29GL512GLXFI-10G (Custom A01) BGA(64) Device

Adapters for Automated Programmers

8th Gen 9th Gen
FVE2ASML64LGT, FVE2ASML64LGT FVE2ASML64LGT

Adapters for Manual Programmers

8th Gen 9th Gen
FVE2ASML64LGT, FVE2ASML64LGT FVE2ASML64LGT

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT: This custom algorithm is for devices on interposer boards (12×14).

Device Type: Flash Memory
Device Size: 512 Mbit
Algorithm Programming method: Parallel Programming


Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address(hex)(if this area is selected/Activated) BPWin Buffer Byte Address(hex)
Main Flash Area R/W/E Yes 0000_0000 – 03FF_FFFF 0000_0000 – 03FF_FFFF
SecSi sector R/W No 0000_0000 – 0000_03FF 0400_0000 – 0400_03FF
4-Word Password R/W No 0000_0000 – 0000_0007 0400_0400 – 0400_0407
Default Algorithm Range 0000_0000 – 03FF_FFFF 0000_0000 – 03FF_FFFF

* R:Read only W:One time programmable (OTP) R/W:readable and one time programmable (OTP) R/W/E:readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:

The SecSi sector can be purchased programmed and locked from the factory. If this is the case this sector needs to be excluded from programming and verification ranges as this data could have a unique number.
The configuration option for the factory lock is used to indicate the status of the chip.
If this option is different than the state of the chip during verification or compare it will cause an error.
If the part has not been locked by the factory the user can treat this sector as an additional memory sector with OTP sector protection.
The 4-Word Password area is mapped from 2000200h-2000203h (Data Pattern Byte locations: 4000400h-4000407h).
Once Password Protection Mode Lock bit is set protected sector groups can no longer be unprotected by this algorithm.
Password area is only verified right after it is programmed with Program operation.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

Manufacturer

Macronix

Packages

BGA(64)

Part Number

MX29GL512GLXFI-10G

Set programming

Yes

Vcc(program)

3.3

Package