Adapters for Automated Programmers
8th Gen | 9th Gen |
FVE4ASMR48QPB, FVE4ASMR48QPB | FVE4ASMR48QPB |
Adapters for Manual Programmers
8th Gen | 9th Gen |
FVE4ASMR48QPB, FVE4ASMR48QPB | FVE4ASMR48QPB |
Adapters for Engineering Programmers
Last Updated: 05/18/2023
If the device is not yet supported by your BPM programmer (Generation), request Device Support
Note
IMPORTANT:
Device Type: | Microcontroller |
Device Size: | 256 KByte Code Flash + 8 KByte Data Flash |
Algorithm Programming Method: | Two-wire UART |
Memory Organization:
Memory Type |
Attributes(*)
|
Included in default Range (Y/N) | DUT Physical Byte Address(hex)(if this area is selected/Activated) | BPWin Buffer Byte Address(hex) |
Code Flash | R/W/E | Yes | 0000_0000 – 0003_FFFF | 0000_0000 – 0003_FFFF |
Data Flash | R/W/E | Yes | 000F_1000 – 000F_2FFF | 000F_1000 – 000F_2FFF |
Default Algorithm Range | — | — | 0000_0000 – 000F_2FFF | 0000_0000 – 000F_2FFF |
* R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:
Option | Description |
Security Flag | Set Bit 1 to 0 will disable Boot cluster rewrite. Set Bit 2 to 0 will disable Block Erase. Set Bit 4 to 0 will disable Program.Bits 0 3 5 6 and 7 are reserved and should be set to 1s.Bit 4 can be erased through Erase.Once bit 2 is programmed to 0 the whole chip is secured and no further operations can be performed.Once Bit 1 is programmed to 0 the boot block clusters specified are secured and no further operations can be performed. |
1. | Boot cluster 0 is located in Clode Flash address 00000h – 01FFFh. Boot cluster 1 is located in Clode Flash address 02000h – 03FFFh. | |
2. | The Security Byte can be set under Device->Configure and programmed with Secure command. | |
3. | Configuration options will only be programmed and verified in the Secure command. | |
4. | Erasing a non-blank device requires selecting the ‘Entire Device’ range under Device->Settings. | |
5. | This algorithm supports Firmware version V3.03 and below. |
‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
8-bit Bytes | 995328 |
---|---|
Manufacturer | Renesas |
Packages | QFP(48) |
Part Number | R5F10PGJCLFB |
Set programming | Yes |
Vcc(program) | 3.3 |
Package |