+1 (713) 688-4600 | Sales Toll-Free: (855) SELL BPM | 24/7 Service: +1 (832) 617-5702 info@bpmmicro.com
Select Page

Renesas R7F701405EAFB#KA0 QFP(176) Device

Adapters for Automated Programmers

8th Gen
FVE2ASMR176QFPA, FVE2ASMR176QFPA

Adapters for Manual Programmers

8th Gen
FVE2ASMR176QFPA, FVE2ASMR176QFPA

Adapters for Engineering Programmers


Last Updated: 05/18/2023

If the device is not yet supported by your BPM programmer (Generation), request Device Support

Note


IMPORTANT:

Device Type: RH850G3M CPU core Microcontroller
Device Size: 5MB Code Flash + 32kB User Area + 64kB Data Flash
Algorithm Programming Method: 3-Wire Serial I/O Mode.

Memory Organization:

Memory Type

Attributes(*)

Included in default Range (Y/N) DUT Physical Byte Address (hex)(if this area is selected/Activated) BPWin Buffer Byte Address (hex)
Code Flash R/W/E Yes 0000_0000 – 004F_FFFF 0000_0000 – 004F_FFFF
User Area Flash R/W/E Yes 0100_0000 – 0100_7FFF 0100_0000 – 0100_7FFF
Data Flash R/W/E Yes FF20_0000 – FF20_FFFF FF20_0000 – FF20_FFFF
Default Algorithm Range 0000_0000 – FF20_FFFF 0000_0000 – FF20_FFFF

*R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:

Option Description
Security Flag Set Bit 5 to 0 will disable Erase. Set Bit 6 to 0 will disable Program. Set Bit 7 to 0 will disable Read.Bits 4 to 0 are reserved and should be set to 1s.The Security Byte cannot be erased and once bit 5 is programmed to 0the whole chip is secured and no further operations can be performed.
1. Verification for this device is performed using the internal CRC feature of the device.
The Data Pattern CRC is compared and validated against the CRC value returned internally by the device.
Device specifications provide details on how this CRC is calculated.
2. The Security Flag can be set under Device->Configure and programmed with Secure command.
3. Security Byte will only be programmed and verified in the Secure command.
4. This algorithm supports Firmware version RH850 V3 or later.
5. Once Validate ICU-S is set to True stand alone verify and compare will not be supported in the Data Flash range.
6. Serialization is not supported.

BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.

Additional information

8-bit Bytes

4280352768

Manufacturer

Renesas

Packages

QFP(176)

Part Number

R7F701405EAFB#KA0

Vcc(program)

3.3

Package