Adapters for Automated Programmers
8th Gen |
FVE4ASML153BGL, FVE4ASMC153BGJ, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASML153BGL, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASMC153BGJ |
Adapters for Manual Programmers
8th Gen |
FVE4ASML153BGL, FVE4ASMC153BGJ, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASML153BGL, FVE4ASMC153FBGEA, FVE4ASMC153BGZ, FVE4ASMC153BGJ |
Adapters for Engineering Programmers
Last Updated: 05/18/2023
If the device is not yet supported by your BPM programmer (Generation), request Device Support
Note
IMPORTANT: This is a custom algorithm. Please contact BPM before using. Data Buffer Organization:
Data File | BPWin Buffer Address (hex) |
CID | 00_0000_0000 – 00_0000_000F |
OCR | 00_0000_1000 – 00_0000_1003 |
CSD | 00_0000_2000 – 00_0000_200F |
Pre-Enhancement ECSD | 00_0000_3000 – 00_0000_31FF |
Post-Enhancement ECSD | 00_0000_4000 – 00_0000_41FF |
Configuration File | 00_0000_5000 – 00_0000_5FFF |
Firmware File | 00_0001_0000 – 00_0008_0BFF |
Boot Partition 0 | 00_0100_0000 – 00_013F_FFFF |
Boot Partition 1 | 00_0140_0000 – 00_017F_FFFF |
User Data Area (Pre-Enhancement) | 00_0180_0000 – 0E_907F_FFFF |
Special Device Considerations:
1. | The algorithm will log the current CID OCR CSD ECSD and various block and health information. | 2. | All values read from the device will be written to a log file located in your Auto Save Job Summary Report directory.This feature must be enabled otherwise the algorithm will fail.To enable please go to File->Configure and check Enable under Auto Save Job Summary Report. |
3. | For the CID the algorithm will check against the CID data file.In particular it will check the MID CBX OID PNM and PRV. |
4. | For the current OCR the algorithm will check against the OCR data file. The entire OCR will be checked. |
5. | For the current CSD the algorithm will check against the CSD data file.The entire CSD except the checksum and stop bit will be checked. |
6. | For the pre-enhancement ECSD the algorithm will check against the pre-enhancement ECSD data file.For TLC devices and for the initial pass on pSLC devices the algorithm will check settings related topSLC enhancement to verify they are in the initial state.The algorithm will also check the MAX_PRE_LOADING_DATA_SIZE[21:18] FIRMWARE_VERSION[261:254]PRE_EOL_INFO[267] DEVICE_LIFE_TIME_EST_TYP_A[268] and DEVICE_LIFE_TIME_EST_TYP_B[269]. |
7. | For the post-enhancement ECSD the algorithm will check against the post-enhancement ECSD data file.For TLC devices the algorithm will just check against the pre-enhancement ECSD data file again. |
8. | The configuration file must list the following fields: CE number Flash ID Grown_BB_Max Ini_BB_Max_PPAverage Erase Count of TLC Average Erase Count of SLC PWR_UP_MAX ABNORMAL_PWR_UP_MAXTEMP_MAX and pSLC. |
9. | The pSLC conversion setting will read from the pSLC field in the configuration file by default.The pSLC conversion can be explicitly disabled under Device->Settings. |
10. | The algorithm will attempt to erase the device (boot partitions and user data area)program the test data loaded in the data buffer verify the data erase the device againand verify that the device is blank. This test will be performed after the pSLC conversionif it is enabled. |
11. | After the data programming and verification tests the previous logging forthe various device register block information and health information will run again.The values used for the ECSD check will change based on the pSLC-related settings. |
12. | Under Device->Settings it is recommended to reduce the High Device Address based on the end of the test data file.This will reduce the time required for the data programming and verification tests. |
13. | Under Device->Settings enabling auto range will skip the blank portions of the data bufferused for the data programming and verification tests.However when verifying that the device is blank the full selected range will be used.The Skip blank checking empty Data Pattern regions setting will reduce the range that is verified to be blankto the same range as the initial programming and verification. |
14. | If using the Field Firmware Update process it must be enabled under Device->Settings. |
‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
8-bit Bytes | 62553849856 |
---|---|
Manufacturer | Smart Modular Technologies |
Packages | BGA(153) |
Part Number | SP9MCGP3AMI01 |
Vcc(program) | 3.3 |
Package |