IMPORTANT: Algorithm support for this device selection is developed. Device samples are needed for QA testing and full release in BPWin.For information on how to obtain an expedited release of this device support please contact BPM Microsystems at:Inside Sales713–688-4600inside_sales@bpmmicro.comInformation on expected socket module support can be found our web page at: http://www.www.bpmmicro.com/find-your-device/**Please note that receipt of device samples and QA testing must be completed before socket module support can be validated.
Device Type: | ARM-based 32-bit MCU with Flash |
Device Size: | 2048 KByte Flash Memory |
Algorithm Programming Method: | JTAG + Custom bootloader |
Memory Organization:
Memory Type |
Attributes(*)
|
Included in default Range (Y/N) | DUT Physical Word Address(hex)(if this area is selected/Activated) | BPWin Buffer Word Address(hex) |
Main Flash Memory | R/W/E | Yes | 400_0000h – 40F_FFFFh | 400_0000h – 40F_FFFFh | Option Bytes | R/W/E | Yes | 0FFF_6000h – 0FFF_6007h | 0FFF_6000h – 0FFF_6007h |
Option Bytes | R/W/E | Yes | 0FFF_E000h – 0FFF_E007h | 0FFF_E000h – 0FFF_E007h |
Default Algorithm Range | — | — | 400_0000h – 40F_FFFFh | 400_0000h – 40F_FFFFh |
* R:Read only W: One time programmable (OTP) R/W: readable and one time programmable (OTP) R/W/E: readable and rewritable if not locked. Any configurations listed under Device-Specific’ in the menu item Device-> Settings will be written to the DUT during ‘Program’ operation regardless of memory range selection. Special Device Considerations:
Option | Description | Default | Supported (Y/N)? |
RDP protection | Option byte 0: at buffer address 1FFF_C000h is used for setting read protection If RDP protection is set to level 1(Non AAh Non CCh) all flash memory cannot be read. If RDP protection is set to level 2(CCh) device debug interface is disabled. Any further operation on device will fail. | Level 0 | Yes |
Stand alone operation might fail if device was programmed with executable code. ‘
BPM does not sell programmable devices, nor do we program devices directly. BPM makes programmers and accessories to make programming in-house fast, easy, and profitable.
Additional information
Manufacturer | STMicroelectronics |
---|---|
Packages | UFBGA(176) |
Part Number | STM32F479IGH7 |
Set programming | Yes |
Vcc(program) | 3.3 |